A single condition
The marked point is 20°C dry bulb and 14°C wet bulb. From that point the other scales can be read.
Open the definitionsTechnology
A psychrometric chart draws the properties of moist air so they can be read rather than calculated. Two known values fix a point. Every other scale is then read off that point. The photograph is an illustration of a chart on a screen. The figures further down are DST’s published chart, with the worked marks printed on it.
Find the point
Dry bulb and relative humidity, or dry bulb and dew point, or any other independent pair.
Read the rest
Humidity ratio, wet bulb, dew point, specific volume and enthalpy are then scales from that point.
A process
Cooling, heating or drying is a line between two points. The chart shows both the temperature change and the moisture change.
The definitions
Each property, and the numbers marked on these figures, is written out on the definitions page.
These are the same charts used on the definitions page. The captions follow the marks on the figure.

The marked point is 20°C dry bulb and 14°C wet bulb. From that point the other scales can be read.
Open the definitions
The curve through 20°C is marked 50% RH. Relative humidity is one of the two values people usually start with.

At 20°C, 50% RH and 7.3 g/kg, the chart marks a dew point of 9.3°C, where that moisture meets the saturation curve.

From 31.5°C and 15.0 g/kg to 10°C and 7.6 g/kg. The chart splits the change into latent heat of 19 kJ/kg and sensible heat of 22 kJ/kg, 41 kJ/kg in total.
These notes describe the method. A sale or a hire is a separate conversation, matched to the site.
Describe the space, the temperature and any humidity or dew point you already know.
Ask about a dutyDry air, Dalton’s law, equilibrium moisture and the full list of quantities, beside every marked chart.
Read the psychrometric definitionsOur office number is 01422 312 562, Monday to Friday, 8.30am to 5.00pm.
Call 01422 312 562No. Two known values locate a point, and the other properties are read from the scales. The formulae are on the definitions page for when a figure has to be calculated rather than read.
The green grid marked DST Humidity Control. The opening photograph is an illustration of a chart on a laptop, not that grid.
The condition of the air. Humidity ratio, dew point, wet bulb, volume and enthalpy then follow, provided the two starting values are independent.
Temperature, the space, and any humidity or dew point you already know.
Or call 01422 312 562
Monday to Friday, 8.30am to 5.00pm