DST industrial dehumidifiers dry air with a silica gel rotor, not by cooling the air below its dew point. That is why they are used in cold stores and ice rinks, and for dew points a refrigerant unit does not reach. The photograph is an installed RLZ-101.

DST RLZ-101 dehumidifier with a green control panel, connected to ductwork
  • The rotor

    Seibu Giken silica gel, chemically bonded. DST states there is no desiccant carry-over, and publishes more than 90% of original capacity after 10 years.

  • How dry

    Minus 60°C dew point in a single pass is the published Flexisorb figure with the D-Max rotor. It is not the figure for every model.

  • The layouts

    Consorb, Recusorb with heat recovery, and Aquasorb with an air-cooled condenser.

  • The panels

    PLC C2 is standard on RLZ, CZ and RF. EH3 and EH4 cover stepped and PI control on the mid-range units.

The industrial series

Each series has its own page. The points below are the published distinctions, not a full specification.

Large beige DST dehumidifier, marked DST 3250, with access doors and a duct connection

Flexisorb

Custom systems built around the rotor, as RF on the Recusorb principle or CF on the Consorb principle. DST publishes process airflows up to 60,000 m³/h. Coils for pre-cooling, post-cooling and post-heating are added when the supply temperature has to be controlled as well.

Open Flexisorb systems
Grey DST dehumidifier with a green control panel and a green fan on the side

RLZ and CZ

Larger units for chemical, pharmaceutical and food processes, warehouses, cold stores, ice rinks and sports halls. RLZ is Aluzinc, with Recusorb heat recovery. CZ is the Consorb series DST describes for deep drying. Reactivation can be electric, steam, direct-fired gas or hot water. Standard equipment includes G4 inlet filters, both fans, the heater, a D-Max rotor and PLC C2.

Open desiccant dehumidifiers
Stainless steel DST dehumidifier with two round duct connections and a green control panel

R and RL

Mid-range stainless units with heat recovery, for dry-air stores, cold stores, sports halls, museums, clean rooms, pneumatic conveying and process air conditioning. Electric reactivation, with steam available. Pre-wired for the EH4, and able to take linear control from the EH3 or a BMS signal.

Open Recusorb dehumidifiers
Stainless DST unit. The top panel is marked DC-50R and D-MAX

DC, DR and Aquasorb

Smaller stainless units for water-damage work, temporary control, museums, laboratories, silo headspace, dry-air stores and small processes. DC is Consorb. DR is Recusorb with one fan. Aquasorb adds the air-cooled condenser so the moisture can be drained. The photograph is a DC-50R.

Open Aquasorb dehumidifiers

Why a desiccant unit

A refrigerant dehumidifier cools air until water condenses. Below a point it loses capacity. A desiccant rotor still takes moisture from cold air, and can be specified for a dew point well below freezing.

DST RLZ-101 dehumidifier with a green control panel, connected to ductwork
  • Cold rooms

    Cold stores and ice rinks are the published examples where the cooling coil is the weaker method and the rotor is the one DST uses.

  • The 90% figure

    DST publishes that the Seibu Giken rotor keeps more than 90% of its original moisture-removal capacity after 10 years of operation.

  • Controls

    Capacity can be two-step, multi-step, binary, or full PI linear, from an EH4, an EH3, or a BMS signal. PLC C4 adds Modbus TCP/IP on the larger units.

Buy, hire or service

This page explains the industrial range. Sales, hire and servicing each have their own enquiry route.

  1. Buy a system

    Permanent supply through industrial dehumidifier sales.

    Go to dehumidifier sales
  2. Hire for a period

    Temporary capacity through industrial dehumidifier hire and rental.

    Go to dehumidifier hire
  3. Service existing plant

    Scheduled industrial dehumidifier servicing for units already installed.

    Go to dehumidifier servicing
  4. The rotor and the layouts

    How Consorb, Aquasorb and Recusorb move the two airstreams.

    Read the desiccant principles
  5. Cooling or a rotor

    Where a refrigerant dehumidifier is the right machine, and where it is not.

    Read refrigeration or desiccant

Questions

Does every industrial unit reach minus 60°C?

No. That single-pass figure is what DST publishes for Flexisorb with the D-Max rotor. The other series are chosen for the dew point the process needs.

What does 90% after 10 years refer to?

DST’s published figure for the Seibu Giken rotor: more than 90% of its original moisture-removal capacity after 10 years of operation.

Which page has the model names?

Consorb, Recusorb and Aquasorb each list the published model names. Flexisorb is specified as a system, as RF or CF, rather than as one fixed size.

Ask about an industrial unit

Give the temperature, the airflow if you know it, and the humidity or dew point. Name a series if one is already in mind. Choose Purchase equipment to buy.

Or call 01422 312 562