Recusorb dehumidifiers

Recusorb is the DST layout with heat recovery inside the rotor. Heat left in the rotor preheats the incoming regeneration air, so the heater uses less energy and the dry air leaves cooler than it does from a Consorb unit.

DST RLZ-101 dehumidifier with a green control panel, connected to ductwork
  • Heat recovery

    The rotor preheats the regeneration air. That heat is already in the unit. It is not a separate exchanger added on site.

  • Cooler dry air

    DST states that the process air leaves cooler and drier than from the other desiccant layouts.

  • Two fans, or one

    R, RL and RLZ use a process fan and a reactivation fan. DR uses one fan for both airstreams.

  • The span

    From the DR-10 through the R and RL series to the RLZ, plus the RLZ ICE variant.

The Recusorb series

DST uses this layout on most of its units, for open or closed systems, including duties where the moisture load changes.

Cutaway of a rotor with separate process and reactivation fans and a heater

Where the heat goes

Process air crosses the larger sector of the rotor and leaves drier. Regeneration air is heated, crosses the smaller sector, and carries the moisture away. On Recusorb, air that has already been warmed by the rotor is used to preheat that regeneration stream before the heater. The heater then has less temperature to add.

Read the desiccant principles
DST dehumidifier between separate filter and coil modules, with a post-cooler section to the right

RLZ

The larger industrial Recusorb units, made in Aluzinc, with internal heat recovery. Used for chemical, pharmaceutical and food processes, large warehouses, cold stores, ice rinks and sports halls. Reactivation can be electric, steam, direct-fired gas or hot water.

As standard, an RLZ has G4 inlet filters, process and reactivation fans, a reactivation heater, a D-Max rotor, an electric panel and PLC C2. Bolt-on Flex modules add cooling, heating or finer filtration.

  • RLZ 81 to 104
  • RLZ ICE
See all desiccant ranges
Stainless steel DST dehumidifier with two round duct connections and a green control panel

R and RL

Mid-range units in 2333 stainless steel, with internal heat recovery, electric reactivation, and auto or manual switching. Steam reactivation is available. They are pre-wired for two-step binary control from the EH4, and can use linear control from the EH3 or a building-management signal.

  • RL60 and RL60L
  • R51 and R61
  • RL61, RL61L and the ICE versions
  • RL71, RL71L and the ICE version

DR, and the add-on modules

Recusorb DR is the same heat recovery with one fan pushing both airstreams. It supplies dry fresh air into a process, or into an open total-loss duct.

  • DR-10 and DR-10 MH1
  • DR-20B
  • DR-30D
  • DR-31 T10
  • DR-40 T10 and DR-40 T16
  • DR-50

The menu also lists the WAC 40 condenser and the PB10/20 fan box with this range.

Recusorb models

Open a model for the published figures and a quote to buy or hire it.

Recusorb DR-010B MH-1

Recusorb DR-010B MH-1

0.5 kg/h. At 20°C / 60% RH.

View product
Recusorb RL-60R and RL-60LR

Recusorb RL-60R and RL-60LR

4–5 kg/h. At 20°C / 60% RH.

View product
Recusorb R-51R and R-61R

Recusorb R-51R and R-61R

7.3–10 kg/h. At 20°C / 60% RH.

View product
Recusorb RL-61, ICE and L

Recusorb RL-61, ICE and L

7.5–11.5 kg/h. At 20°C / 60% RH.

View product
Recusorb RL-71 and ICE

Recusorb RL-71 and ICE

13–17 kg/h. At 20°C / 60% RH.

View product
Recusorb RLZ-81 to RLZ-104

Recusorb RLZ-81 to RLZ-104

19–70 kg/h. At 20°C / 60% RH.

View product
WAC-40 condenser

WAC-40 condenser

Wet air. Condensed, not ducted out.

View product

When Recusorb is the layout

DST describes it for continuous or high moisture loads, and for rooms that stay cold. Consorb remains the simpler path when the load is steady and heat recovery is not needed.

Two people in green workwear and hard hats looking at a plant display
  • Longer running

    The recovered heat cuts the energy the reactivation heater has to put in. That is the published reason for choosing Recusorb on a plant that runs for long periods.

  • Cooler supply air

    Because some of the adsorption heat stays with the rotor and moves into the regeneration air, the dry air does not leave as hot as it does from Consorb.

  • Where it sits

    A unit can stand alone or be ducted. Published places include plant rooms, mezzanines and the production area itself.

Next step

  1. The simpler layout

    Consorb uses one fan and a fixed regeneration airflow, without the heat recovery sector.

    Open Consorb dehumidifiers
  2. All of the desiccant ranges

    Flexisorb, RLZ, R and RL, and the smaller DC, DR and Aquasorb units.

    Open desiccant dehumidifiers
  3. Buying in the UK

    Newsome supplies the DST range. Name a model, or describe the duty if it is not chosen yet.

    Go to dehumidifier sales

Questions

What does the heat recovery actually do?

Heat already in the rotor warms the incoming regeneration air before the heater. DST states that this cuts heater energy and leaves the dry process air cooler and drier than the other layouts.

Is every Recusorb a two-fan unit?

R, RL and RLZ have a process fan and a reactivation fan. DR uses one fan for both airstreams, and is the layout drawn for dry fresh air into a process or an object.

Which models are in the range?

DR-10, DR-10 MH1, DR-20B, DR-30D, DR-31 T10, DR-40 T10, DR-40 T16, DR-50, RL60/60L, R51/61, RL61/61L/ICE, RL71/71L/ICE, RLZ 81 to 104 and RLZ ICE. The WAC 40 condenser and PB10/20 fan box are listed with them.

Ask about a Recusorb

Give the temperature, the space, and the humidity or dew point. Name a model if you already have one in mind. Choose Purchase equipment to buy.