PLC C2
The photograph is the C2:1 dehumidifier controller. Used with an EH3, an EH4, or an external controller, it sets the drying capacity to the setpoint.
- Digital inputs9
- Digital outputs7
- Analogue inputs4
- Analogue outputs2
DST controls
DST publishes PLC C2 as standard on RLZ, CZ and RF units, with C4 where the panel has to show the whole system. EH3 and EH4 are the separate humidistats. A C7 is also named. Its input count is not published on this page.
C2
Keypad and a two-row backlit LCD. Standard on the industrial RLZ, CZ and RF units.
C4
5.7 inch colour touchscreen, with a graphic of the main components and their live readings.
EH3
PI control of relative humidity, absolute humidity, dew point or temperature. Two independent controllers.
EH4
Two programmable relays for relative humidity, with adjustable hysteresis.
A PLC can run on its own, with an EH3 or EH4, or from a building-management signal. The PLC’s published jobs are the interface, sequencing the main components, watching trips and alarms, and adjusting capacity for humidity, airflow and temperature.

The photograph is the C2:1 dehumidifier controller. Used with an EH3, an EH4, or an external controller, it sets the drying capacity to the setpoint.

A colour display of the principal components, with access to the menus on a 5.7 inch backlit screen. DST publishes a PC tool, and describes it as free, for watching and changing the PLC over the internet.

The face of the unit lists the four readings. Each controller is independent.
Published options are a mounted temperature sensor that floats the dew-point setpoint to avoid condensation, a duct temperature sensor, Modbus RTU, and extra displays.

Two closing contacts. Each relay is programmed on its own, with adjustable hysteresis, and can call for dehumidification or humidification. The published uses are high, low or off on one unit, on or off on two units, or one unit plus a remote high and low RH alarm.
The display is 15 mm. Indicator lamps show which relay is closed, and the display flashes if the high RH setpoint is passed. The sensor is a Honeywell capacitive type, IP65, factory calibrated. DST states the accuracy as better than ±2% RH. Sensors are published for wall or duct mounting, with a 3 m cable. The display and keypad can be mounted remotely on an RJ9 cable.
These pairings are already on the range pages. They are collected here so the panel is chosen with the machine.

PLC C2 is the standard panel. PLC C4, with Modbus TCP/IP, is the published option on RLZ and CZ when the control has to be extended.
Pre-wired for two-step binary control from the EH4. Linear control is from the EH3 or a building-management signal.
Auto or manual switching, pre-wired for a humidistat on an Amphenol plug.
Flexisorb, RLZ, CZ, R and RL, and the smaller DC, DR and Aquasorb units.
Open industrial dehumidifiersSensors, humidistats, EH3, EH4 and C2 parts are covered with the spares enquiry.
Open dehumidifier sparesName the unit if the controller is for a machine already chosen.
Go to dehumidifier salesThe EH3 is a PI controller for relative humidity, absolute humidity, dew point or temperature, with two independent controllers. The EH4 is two programmable relays for relative humidity, for stepped control of one or two units.
DST publishes PLC C2 as standard on its industrial RLZ, CZ and RF dehumidifiers. R and RL units are pre-wired for the EH4, with the EH3 or a BMS signal for linear control.
DST names a C7 alongside the C2 and C4. The input and output counts on this page are only the published C2 and C4 figures.
Name the dehumidifier and whether the setpoint is relative humidity, absolute humidity or dew point. Choose Purchase equipment to buy.